Try searching by key words, order- or product code or serial number e.g. “CM442” or “Technical information”
Enter at least 2 characters to start the search.
Gamma Source FSG60 - Radiometric measurement

Radiometric level and
density measurement
Gamma Source FSG60

Gamma radiation source (137Cs) for radiometric level, point level, density and interface measurement

FSG60
Please Wait (spinning wheel)
Loading price
Prices temporarily unavailable
Price on request
activating price
price: provide information
from CHF ??.-
Filter Measuring / Application task
Measuring / Application task

Configure to download the CAD drawings of this product

  • Measuring principle

    Radiometric

  • Characteristic / Application

    Source
    Isotope: Caesium 137
    Half-life: 30 years

  • Specialities

    Double seal
    Steel: 1.4541 (321 S 18)
    Classification C66646 ISO 2919

  • Ambient temperature

    -20°C ... +250 °C
    (-4°F ... 482 °F)

  • Process pressure / max. overpressure limit

    Any

  • Pressure measuring range

    Any

  • Components

    Installed in source container

  • Measuring principle

    Radiometric

  • Characteristic / Application

    Source
    Isotope: Caesium 137
    Half-life: 30 years

  • Specialities

    Double seal
    Steel: 1.4541 (321 S 18)
    Classification C66646 ISO 2919
    Activity calculation with
    Applicator

  • Ambient temperature

    -20°C ... +250 °C
    (-4°F ... 482 °F)

  • Process pressure / max. overpressure limit

    Any

  • Components

    Installed in source container

  • Measuring principle

    Radiometric Limit

  • Characteristic / Application

    Source
    Isotope: Caesium 137
    Half-life: 30 years

  • Specialities

    Double seal
    Steel: 1.4541 (321 S 18)
    Classification C66646 ISO 2919
    Activity calculation with
    Applicator

  • Ambient temperature

    -20°C ... +250 °C
    (-4°F ... 482 °F)

  • Process pressure / max. overpressure limit

    Any

  • Components

    Installed in source container

  • Measuring principle

    Radiometric Limit

  • Characteristic / Application

    Source
    Isotope: Caesium 137
    Half-life: 30 years

  • Specialities

    Double seal
    Steel: 1.4541 (321 S 18)
    Classification C66646 ISO 2919
    Activity calculation with
    Applicator

  • Ambient temperature

    -20°C ... +250 °C
    (-4°F ... 482 °F)

  • Process pressure / max. overpressure limit

    Any

  • Components

    Installed in source container

  • Measuring principle

    Radiometric Density

  • Characteristic / Application

    Source
    Isotope: Caesium 137
    Half-life: 30 years

  • Ambient temperature

    -20 °C ... +250 °C

  • Specialities

    Double seal
    Steel: 1.4541 (321 S 18)
    Classification: C66646 ISO 2919
    Activity calculation with
    Applicator

  • Components

    Installed in source container