Specs at a glance
Input
Chor / Chlordioxide and pH/ORP Sensor.
Output / communication
- Chlor/Chlordioxid, pH, Temperatur : 0/4-20mA- Profibus- Hart + 0/4-20mA
Field of application
Liquisys CCM223 is a standard chlorine transmitter with integrated pH compensation for free chlorine. It improves your operational safety thanks to continuous plausibility, process and sensor checks. Select from numerous hardware and software modules, such as relays or fieldbus communication, to adapt it exactly to your measuring task. This modularity also allows you to upgrade the transmitter at any time. A simple menu and calibration make configuration and operation fast and easy.
The Liquisys CCM223 transmitter works with all analog total chlorine, free chlorine, chlorine dioxide and pH sensors in:
Water & Wastewater - Disinfection process control and monitoring - Desalination with membrane technology - Swimming and whirl pools - Gas scrubbers
Food & Beverages - Disinfection of process water
Power plants - Cooling water disinfection
Liquisys CCM223 features the following protocols and interfaces:
0/4...20mA
HART
PROFIBUS DP
PROFIBUS PA
Benefits
More operational safety: Continuous process check system, customized alarm configuration, calibration plausibility check.
Reliable chlorine and pH control: Current input for flow rate monitoring with controller shut off or for feedforward control.
Easy to operate and service: Intuitive user interface, simple calibration for chlorine and pH, direct access for manual contact control.
Reduced maintenance: Automatic cleaning function (with Chemoclean) triggered by alarm or limit switch.
Fit for every application: Numerous extensions, e.g. P(ID) controller, timer, etc., allow for flexible adaption to all processes.
Simple products
Easy to select, install and operate
Technical excellence
Simplicity
Standard products
Reliable, robust and low-maintenance
Technical excellence
Simplicity
High-end products
Highly functional and convenient
Technical excellence
Simplicity
Specialized products
Designed for demanding applications
Technical excellence
Simplicity
FLEX selections
Technical excellence
Simplicity
Fundamental selection
Meet your basic measurement needs
Technical excellence
Simplicity
Lean selection
Handle your core processes easily
Technical excellence
Simplicity
Extended selection
Optimize your processes with innovative technologies
Technical excellence
Simplicity
Xpert selection
Master your most challenging applications
Technical excellence
Simplicity
Application
Drinking water, water, waste water process, pool
Characteristic
4-wire transmitter for free chlorine/Chlordioxide in a panel housing. Simple Calibration via "CAL"-button.
Design
Overload protection, alarm relais, different controller functions (P(ID)), temperature display, 2-line display, current output galvanically separated.
Dimension
96mm x 96mm, built in depth : 146mm.
Input
Chor / Chlordioxide and pH/ORP Sensor.
Output / communication
- Chlor/Chlordioxid, pH, Temperatur : 0/4-20mA- Profibus- Hart + 0/4-20mA
Most downloaded
Technical Information CCM 223/
English version - 10/2013
Measurement of chlorine / chlorine dioxide / total chlorine
Transmitter for chlorine sensors
EN
DE FR IT JA ZH
24/10/2013
20/06/2011
01/07/2006
01/09/2000
Language:
English
Version:
24/10/2013
File size:
642.3 KB
File name:
TI00214CEN_1413.pdf
Liquisys M CLM223/253
Operating Instructions
English version - 09/2015
Transmitter
EN
DA DE ES FI FR HU IT JA PL PT RO RU ZH
01/09/2015
24/10/2013
20/06/2011
01/10/2008
15/09/2005
Language:
English
Version:
01/09/2015
File size:
2.5 MB
File name:
BA00193CEN_1515.pdf
24 documents
Technical Information CCM 223/
Measurement of chlorine / chlorine dioxide / total chlorine Transmitter for chlorine sensors
EN
German French Italian Japanese Chinese
24/10/2013
20/06/2011
01/07/2006
01/09/2000
Language:
English
Version:
24/10/2013
File size:
642.3 KB
File name:
TI00214CEN_1413.pdf
Operating Instructions Liquisys M CXM223/253 PROFIBUS
Field Communikation for Liquisys M CXM223/253
EN
German French Italian Polish
01/12/2011
01/08/2009
01/09/2007
01/07/2006
01/10/2005
Language:
English
Version:
01/12/2011
File size:
1.7 MB
File name:
BA209CEN_1311.pdf
Liquisys M CLM223/253
Operating Instructions
Transmitter
EN
Danish German Spanish Finnish French Hungarian Italian Japanese Polish Portuguese Romanian Russian Chinese
01/09/2015
24/10/2013
20/06/2011
01/10/2008
15/09/2005
Language:
English
Version:
01/09/2015
File size:
2.5 MB
File name:
BA00193CEN_1515.pdf
Liquisys M CPM223/253
Operating Instructions
Transmitter
EN
Czech Danish German Spanish Finnish French Hungarian Italian Japanese Polish Portuguese Russian Chinese
01/09/2015
24/10/2013
20/06/2011
01/12/2005
01/03/2005
Language:
English
Version:
01/09/2015
File size:
2.7 MB
File name:
BA00194CEN_1515.pdf
Liquisys M COM223/253
Operating Instructions
Transmitter
EN
Czech Danish German Spanish French Italian Japanese Dutch Polish Portuguese Russian Chinese
01/09/2015
24/10/2013
20/06/2011
15/09/2005
01/07/2005
Language:
English
Version:
01/09/2015
File size:
2.4 MB
File name:
BA00199CEN_1515.pdf
Operating Instructions Liquisys M CXM223/253 HART
Field Communication with Liquisys M CXM223/253
EN
German French
01/10/2005
01/07/2002
Language:
English
Version:
01/10/2005
File size:
541.4 KB
File name:
BA208CEN.pdf
Liquisys M CCM223/253
Operating Instructions
Transmitter
EN
Czech German Spanish French Hungarian Italian Japanese Polish Portuguese Russian Chinese
27/08/2015
24/10/2013
20/06/2011
01/07/2006
01/02/2003
Language:
English
Version:
27/08/2015
File size:
2.7 MB
File name:
BA00214CEN_1515.pdf
Ex-safety instructions CXM2X3
Safety instructions for electrical apparatus for explosion-hazardous areas as per EC Directive 94/9/EC (ATEX)
EN
German French
07/06/2005
27/09/2004
29/02/2004
Language:
English
Version:
07/06/2005
File size:
2.5 MB
File name:
XA194CA3.pdf
Additional information for CSA Liquisys
Additional information for CSA Liquisys
Language:
English
Version:
24/09/2013
File size:
84.3 KB
File name:
CXM2X3_Beiblatt for CSA.pdf
Product family: Liquisys chlorine, Liquisys conductivity, Liquisys oxygen, Liquisys pH/ORP
Product root: CCM223-, CCM253-, CLM223-, CLM253-, COM223-, COM253-, CPM223-, CPM253- Declaration number: EC_00575_02.23
EN
German French
17/07/2023
Language:
English
Version:
17/07/2023
File size:
321 KB
File name:
EC_00575_02.23_CxM2x3.pdf
60 spare parts & accessories
60 spare parts & accessories
60 spare parts & accessories
Kit CXM2X3 Relaismod. 2rel
KIT CXM2X3 relay mod. 2rel / CSA
Drawing number
Order code
30
51511446
Kit CXM2X3 Relaismodule 4rel
Drawing number
Order code
35
51500321
KIT CXM2X3 relay mod. 4rel / CSA
Drawing number
Order code
35
51511447
Kit CXM2X3 Relais Mod. 2rel.+I/CSA
Drawing number
Order code
40
51504304
Kit CXM2X3 Relais Mod. 4Rel+I/CSA
Drawing number
Order code
45
51504305
KIT CXM2X3 power supply 100..230 V AC
Drawing number
Order code
10
51500317
KIT CxM2x3 power supply 24 AC/DC
Drawing number
Order code
20
51500318
Kit CXM223 housing assembly
Drawing number
Order code
130
51501075
KIT CXM223 Mechanical housing parts
Drawing number
Order code
310,320,34
51501076
Drawing number
Order code
220
51502124
Kit CXM223 End frame Profibus DP
Drawing number
Order code
190
51502513
KIT CXM223 Terminal strip
Drawing number
Order code
180
51501078
KIT MKC1 MEK transmitter Cl wo pH non Ex
Drawing number
Order code
110
51502466
Kit MKC1 MEK transmitter Cl+pH non Ex
Drawing number
Order code
120
51502465
Kit CCM2x3 Central module I1
Drawing number
Order code
50
51502467
Kit CCM2x3 central module I1 HART
Drawing number
Order code
70
51502497
Kit CCM2x3 Central module I2
Drawing number
Order code
60
51502468
Kit CCM2x3 central module I2 HART
Drawing number
Order code
80
51502496
Kit CCM2X3 central module Profibus PA
Drawing number
Order code
90
51502495
Kit CCM2X3 central module Profibus DP
Drawing number
Order code
100
51502498
Kit CCM2x3: Central mod. PB DP; H/W 2.1x
Drawing number
Order code
100
71134731
Kit CxM2x3: Relay mod. for PBDP; H/W2.1x
Drawing number
Order code
30
71134732
Kit CCM223 terminal strip, mA + HART
Drawing number
Order code
150
51502463
Kit CCM223 terminal strip, Profibus DP
Drawing number
Order code
170
51502490
Kit CCM223 terminal strip, Profibus PA
Drawing number
Order code
180
51502464
Kit CxM223: Front foil + 6 key lifters
Drawing number
Order code
335
71071440
Upgrade "Plus-Package" for LIQUISYS-M
Upgrade cleaning for LIQUISYS-M
Upgrade "pH-Package for CCM 2X3-EK"
Upgrade "pH-Package for CCM 2X3-ES"
Mounting bracket 96x96 Housing
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our privacy policy .
Customize
Accept only essential
Accept all