Liquiline System CAT860- Sample preparation system for demanding applications

Sample preparation
Liquiline System CAT860

Robust in-situ filtration system for sampling from inlets of wastewater treatment plants

CAT860
Please Wait (spinning wheel)
Loading price
Prices temporarily unavailable
Price on request
activating price
price: provide information
from CHF ??.-
Filter Measuring / Application task
Measuring / Application task

Configure to download the CAD drawings of this product

  • Measuring principle

    Colorimetric

  • Characteristic

    Automatic sample preparation system for supplying process measuring devices with filtered samples

  • Size

    793 x 530 x 463 mm
    31.22 x 20.87 x 18.23 in
    (h x w x d)

  • Design

    Back-flush filter system with various filter mounting options: float, chain and immersion pipe
    Full compatibility to holder CYH112

  • Process temperature

    4 to 40 °C (39 to 104 °F)

  • Ambient temperature

    Unheated: 5 to 50 °C (41 to 122 °F)
    Heated: -20 to 50 °C (-4 to 122 °F)

  • Process pressure

    Unpressurized

  • Specials

    Back-flush function with cleaner and pressurizd air
    Controlling and parametrization via Liquiline System CA80 with detailed diagnostic function

  • Application

    Sampling from inlet of municipal and industrial wastewater treatment plants. Sampling of aqueous media from industrial processes.

  • Power supply

    100 to 120/200 to 240 V AC 10%, 50/60 Hz

  • Consumables

    Cleaner CY820 for filter and hoses