Try searching by key words, order- or product code or serial number e.g. “CM442” or “Technical information”
Enter at least 2 characters to start the search.
Product image iTHERM TMS31 MultiSens

iTHERM MultiSens Bundle TMS31
Multipoint thermometer

Direct contact TC/RTD temperature profiling solution with flexible metal rope for silos and storage tank applications

TMS31
Please Wait (spinning wheel)
Loading price
Prices temporarily unavailable
Price on request
activating price
price: provide information
from CHF ??.-
Filter Measuring / Application task
Measuring / Application task

Configure to download the CAD drawings of this product

  • Measuring principle

    Resistance Temperature Detector

  • Characteristic / Application

    metric style
    imperial style
    easy-to-use
    suitable for hazardous areas
    process connection: flanged
    Storage applications
    linear sensor distribution
    modular design

  • Thermowell / protection tube

    without (not intended to use with thermowell)

  • Insert / probe

    mineral insulated (MI), flexible

  • Outer diameter protection tube / Insert

    25 mm
    37 mm

  • Max. immersion length on request

    up to 60.000,00 mm (2.360'')

  • Material protection tube/ thermowell

    1.4401 (316)
    1.4435 (316L)

  • Process connection

    flange:
    1 1/2" ASME/ANSI B16.5 150
    ...300
    2" ASME/ANSI B16.5 150
    ...300
    3" ASME/ANSI B16.5 150
    ..300
    4"ASME/ANSI B16.5 150
    ..300
    DN40 EN/DIN 1092.1 PN16
    ...PN40
    DN50 EN/DIN 1092.1 PN16
    ...PN40
    DN80 EN/DIN 1092.1 PN16
    ...PN40
    DN100 EN/DIN 1092.1 PN16
    ...PN40

  • Tip shape

    straight

  • Operating temperature range

    Type K:
    max. 800 °C
    (max. 1.472 °F)
    Type J:
    max. 520 °C
    (max. 968 °F)
    Pt100 WW:
    -200...600 °C
    (-328…1.112 °F)
    Pt100 iTHERM StrongSens:
    -50…500 °C
    (-58…932 °F)
    Pt100 TF:
    -50…400 °C
    (-58...752 °F)

  • Max. process pressure (static)

    at 20 °C: 40 bar (580 psi)

  • Accuracy

    class 1 acc. to IEC 60584
    class 2 acc. to IEC 60584
    class Special ASTM E230 and ANSI MC 96.1
    IEC60751 Class A
    IEC60751 Class AA

  • Response time

    TC
    t50 = 1 s
    t90 = 2 s
    RTD
    t50 = 3 s
    t90 = 6 s

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex - approvals

    ATEX
    IECEX
    UL
    FM
    CSA
    EAC

  • Certification

    SIL (transmitter only)