Product picture of: Prosonic S FDU96

Prosonic S FDU96

FDU96
Please Wait (spinning wheel)
Loading price
Prices temporarily unavailable
Price on request
activating price
price: provide information
from CHF ??.-
Filter Measuring / Application task
Measuring / Application task
  • Characteristic / Application

    Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter

  • Supply / Communication

    4-wire (HART , Profibus DP)

  • Accuracy

    +/- 2mm + 0.17% of measured distance

  • Ambient temperature

    -40 °C ... 150 °C
    (-40 °F ... 302 °F)

  • Process temperature

    -40 °C ... 150 °C
    (-40 °F ... 302 °F)

  • Process pressure / max. overpressure limit

    0.7 bar ... 3 bar abs
    (10 psi ... 44 spi)

  • Main wetted parts

    UP (unsaturated polyester)
    Silicon / Al PTFE coated

  • Process connection

    G / NPT 1"

  • Blocking distance

    1.6 m (5 ft)

  • Max. measurement distance

    70 m (230 ft)

  • Communication

    Transmitter:
    4 ... 20 mA HART
    Profibus DP

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, NEPSI

  • Options

    Second 4...20mA output

  • Components

    Transmitter:
    FMU90