Try searching by key words, order- or product code or serial number e.g. “CM442” or “Technical information”
Enter at least 2 characters to start the search.
Product picture of: Omnigrad M TR48

Omnigrad M TR48

TR48
Please Wait (spinning wheel)
Loading price
Prices temporarily unavailable
Price on request
activating price
price: provide information
from CHF ??.-
Filter Measuring / Application task
Measuring / Application task
  • Characteristic / Application

    metric style
    modular temperature assembly
    hygienic design
    hygienic process connection
    with neck

  • Thermowell / protection tube

    without (not intended to use with thermowell)

  • Insert / probe

    mineral insulated (MI), flexible

  • Outer diameter protection tube / Insert

    4,5 mm (0,18'')

  • Max. immersion length on request

    up to 300,00 mm (11,81'')

  • Material protection tube/ thermowell

    1.4435 (316L)

  • Process connection

    weld in version
    hygienic:
    welded (spherical)
    welded with compression fitting

  • Tip shape

    reduced

  • Surface roughness Ra

    0,4 μm (15,7 μin.)
    0,8 μm (31,5 μin.)

  • Operating temperature range

    PT 100:
    -50 °C ...200 °C
    (-58 °F ...392 °F)

  • Max. process pressure (static)

    at 20 °C: 140 bar (2.031 psi)

  • Accuracy

    class A acc. to IEC 60751
    1/3 DIN class B acc. to IEC 60751

  • Response time

    depending on configuration
    t50 = 3 s
    t90 = 10 s

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex - approvals

    ATEX

  • Certification

    Gost Metrology
    FDA
    SIL (transmitter only)