Try searching by key words, order- or product code or serial number e.g. “CM442” or “Technical information”
Enter at least 2 characters to start the search.
Product picture of: Omnigrad M TSC110S

Omnigrad M TSC110S

TSC110S
Please Wait (spinning wheel)
Loading price
Prices temporarily unavailable
Price on request
activating price
price: provide information
from CHF ??.-
Filter Measuring / Application task
Measuring / Application task
  • Characteristic / Application

    Process industry, straight tip

  • Thermowell / protection tube

    Included, fabricated

  • Insert / probe

    M.I. cable replaceable

  • Process connection

    Thread: G1/2"

  • Operating temperature range

    K: -40...1100°C
    J: -40...750°C

  • Max. process pressure (static)

    50 bar

  • Accuracy

    Class 2

  • Response time

    t50 = 27 s
    t90 = 70 s

  • Integration head transmitter

    PCP 4...20 mA, HART, PROFIBUS-PA

  • Successor

    TC10 avail. March 2004