Try searching by key words, order- or product code or serial number e.g. “CM442” or “Technical information”
Enter at least 2 characters to start the search.
Picture of electromagnetic flowmeter Proline Promag 10P for chemical and process applications

Promag 10P

10P
Please Wait (spinning wheel)
Loading price
Prices temporarily unavailable
Price on request
activating price
price: provide information
from CHF ??.-
Filter Measuring / Application task
Measuring / Application task

Configure to download the CAD drawings of this product

  • Measuring principle

    Electromagnetic

  • Product headline

    std_productprofile_product_usp_34716_1509006628.
    Dedicated to chemical and process applications with corrosive liquids and high medium temperatures.

  • Sensor features

    Diverse applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
    Nominal diameter: max. DN 600 (24"). std_successorproducts_product_differentiating_tech_features_35249_1509523846. std_successorproducts_product_differentiating_tech_features_35251_1509523847.

  • Transmitter features

    std_productprofile_product_benefits_34707_1508943674. std_productprofile_product_benefits_34705_1508943673. std_productprofile_product_benefits_34706_1508943673.
    2-line display with push buttons. Device as compact or remote version. HART.

  • Nominal diameter range

    DN 15 to 600
    1/2" to 24"

  • Wetted materials

    Liner: PTFE
    Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)

  • Measured variables

    Volume flow

  • Max. measurement error

    Volume flow: ±0,5% o.r. ± 2 mm/s (±0,5% o.r. ± 0,08 in/s)

  • Measuring range

    4 dm3/min to 9600 m3/h (0.5 gal/min to 44000 gal/min)

  • Max. process pressure

    PN40
    Cl. 300
    JIS 20K
    AS 2129 Table E

  • Medium temperature range

    –40 to +130°C (–40 to +266°F)

  • Ambient temperature range

    –40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

    DN 15 to 300 (½ to 12"): AlSi10Mg, coated
    DN 350 to 600 (14 to 24"): Carbon steel with protective varnish

  • Transmitter housing material

    Powder-coated die-cast aluminum

  • Degree of protection

    Standard: IP 67 (Type 4X enclosure) for transmitter and sensor
    Optional: IP 68 (Type 6P enclosure) for remote version of sensor

  • Display/Operation

    2‐line display with push buttons
    Configuration via local display and operating tools possible

  • Outputs

    4‐20 mA HART (active)
    Pulse/switch output (passive)

  • Inputs

    None

  • Digital communication

    HART

  • Power supply

    DC 11 to 40 V
    AC 85 to 250 V (45 to 65 Hz)
    AC 20 to 28 V (45 to 65 Hz)

  • Hazardous area approvals

    FM
    CSA

  • Product safety

    CE, C-tick, EAC marking

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)

  • Pressure approvals and certificates

    PED