Try searching by key words, order- or product code or serial number e.g. “CM442” or “Technical information”
Enter at least 2 characters to start the search.
Liquipoint FTW33 - Conductive point level switch

Conductive
Point level detection
Liquipoint FTW33

Very compact flush-mounted probe for liquid and pasty media

FTW33
Please Wait (spinning wheel)
Loading price
Prices temporarily unavailable
Price on request
activating price
price: provide information
from CHF ??.-
Filter Measuring / Application task
Measuring / Application task

Configure to download the CAD drawings of this product

  • Measuring principle

    Conductive

  • Characteristic / Application

    Compact point level switch for using in pipes and in storage, mixing and process vessels with or without an agitator, for water based or oil based media, with active build up compensation,flush mounting

  • Specialities

    CIP and SIP suitable
    Conductive foam is detectable or can be switched off

  • Supply / Communication

    10…30 V DC

  • Ambient temperature

    -40 ... 70°C
    (-40 ... 158°F)

  • Process temperature

    Standard:
    -20 ... 100°C
    Cleaning:
    -20 ... 150°C for 1h
    ( -4 ... 302°F for 1h)

  • Process pressure / max. overpressure limit

    Vacuum ... 25 bar
    (Vacuum ... 362,5 psi)

  • Main wetted parts

    Sensor: 316L
    Sensor isolation: PEEK

  • Process connection

    Thread G1, G1/2, G3/4, M24

  • Process connection hygienic

    Clamp ISO 2852 1 to 1 1/2", 2",
    DIN11851 Pipe union

  • Communication

    DC PNP

  • Certificates / Approvals

    CSA C/US

  • Design approvals

    EN 10204-3.1

  • Hygienic approvals

    3A, EHEDG

  • Options

    Weld-in adapter,
    Process adapter for hygienic process connections