Try searching by key words, order- or product code or serial number e.g. “CM442” or “Technical information”
Enter at least 2 characters to start the search.
Radar measurement - Micropilot FMR244

Micropilot M FMR244

FMR244
Please Wait (spinning wheel)
Loading price
Prices temporarily unavailable
Price on request
activating price
price: provide information
from CHF ??.-
Filter Measuring / Application task
Measuring / Application task

Configure to download the CAD drawings of this product

  • Characteristic / Application

    Characteristic / Application

  • Supply / Communication

    2-wire (HART / PROFIBUS PA / FOUNDATION Fieldbus)

  • Frequency

    K-band (~26 GHz)

  • Accuracy

    +/- 3 mm

  • Ambient temperature

    -40 °C...+80 °C
    (-40 °F...+176 °F)

  • Process temperature

    -40 °C...+130 °C
    (-40 °F...+266 °F)

  • Process pressure / max. overpressure limit

    Vacuum...3 bar
    (Vacuum...43.5 psi)

  • Main wetted parts

    PVDF, PTFE, PP, PBT

  • Process connection

    Thread:
    NPT 1 1/2, G 1 1/2
    Slip on flange:
    DN80...DN150 (3"...6"),

  • Application

    Application

  • Max. measurement distance

    Max. measurement distance

  • Communication

    4...20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, IECEx, TIIS, NEPSI
    Overfill prevention WHG
    SIL
    Marine GL/ABS/NK

  • Application limits

    Application limits

  • Characteristic / Application

    Non-contact level measurement in powdery to granular bulk solids up to 15m measurering range. Applications with highly abrasive bulk solids e.g. ferrite / glas ...

  • Supply / Communication

    2-wire (HART / PROFIBUS PA / FOUNDATION Fieldbus)

  • Frequency

    K-band (~26 GHz )

  • Antenna

    Horn DN80/3"

  • Accuracy

    +/- 15 mm (or 0.04% of range, whatever is larger)

  • Ambient temperature

    -40 °C...+80 °C
    (-40 °F...+266 °F)

  • Process temperature

    -40 °C...+80 °C
    (-40 °F...+266 °F)

  • Process pressure / max. overpressure limit

    Vacuum... 3bar
    (Vaccum... 43.5 psi)

  • Main wetted parts

    PP, PBT, Silicone

  • Process connection

    Flange:
    UNI DN80...DN150

  • Max. measurement distance

    15m (49 ft)(Option F)

  • Communication

    4...20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, IECEx, TIIS, NEPSI

  • Options

    Separate display
    Mounting bracket
    variable flange seal for adjustment

  • Successor

    Micropilot FMR56

  • Application limits

    Dk < 1.6