Try searching by key words, order- or product code or serial number e.g. “CM442” or “Technical information”
Enter at least 2 characters to start the search.
Liquiphant FTL50 - Vibronic

Vibronic
Point level detection
Liquiphant FTL50

Compact vibration point level switch for liquids in all industries

FTL50
Please Wait (spinning wheel)
Loading price
Prices temporarily unavailable
Price on request
activating price
price: provide information
from CHF ??.-
Filter Measuring / Application task
Measuring / Application task

Configure to download the CAD drawings of this product

  • Measuring principle

    Vibration Liquids

  • Characteristic / Application

    Modular housing concept
    wide range of process connections
    Analogue and bus interfaces
    Extensive certificate range (e.g. Ex,WHG)
    compact, e.g. pipes

  • Specialities

    Foamdetection
    Detekt a densitychange
    second line of defense

  • Supply / Communication

    PROFIBUS PA
    19...253V AC
    10...55V DC-PNP
    19...253V AC or 10...55V DC
    8/16mA, 11...36V DC
    NAMUR
    PFM

  • Ambient temperature

    -50 °C...+70 °C
    (-58 °F...+158 °F)

  • Process temperature

    -50 °C...+150 °C
    (-58 °F...+302 °F)

  • Process pressure / max. overpressure limit

    Vacuum...64 bar
    (Vacuum...928 psi)

  • Min. density of medium

    0.5g/cm³(0.4g/cm³ option)

  • Main wetted parts

    316L, Alloy

  • Process connection

    Thread:
    G3/4A, G1A, R3/4", R1, NPT3/4, NPT1
    Flange:
    DN25...DN100,
    ASME 1"...4",
    JIS 25A...100A

  • Process connection hygienic

    Tri-Clamp ISO2852

  • Communication

    PROFIBUS PA
    19...253V AC
    10...55V DC-PNP
    19...253V AC or 10...55V DC
    8/16mA, 11...36V DC
    NAMUR
    PFM

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI

  • Safety approvals

    SIL2/ SIL3

  • Design approvals

    EN 10204-3.1
    NACE MR0175, MR0103
    ASME B31.3
    AD2000

  • Marine approval

    GL/ ABS/ DNV

  • Options

    Heavy duty stainless steel housing mainly for the oil and gas industry

  • Components

    FTL325P/FTL375P Interface PFM
    FTL325N/FTL375N Interface NAMUR

  • Successor

    Liquiphant FTL51B

  • Measuring principle

    Vibration Density

  • Characteristic / Application

    Liquiphant M Density
    with Density Computer FML621
    Temperature and pressure measurement
    Modular housing concept
    Wide range of process connections

  • Supply / Communication

    Transmitter power supply (MUS)

  • Ambient temperature

    -50...70°C
    -50...60°C for hazardous applications

  • Process temperature

    0...80°C (validity of accuracy data)
    -50...0°C /80...150°C (with reduced technical data)

  • Process pressure

    0...25 bar
    >25...64 bar (with reduced technical data)

  • Wetted parts

    316L/C4

  • Sensor length

    Compact: 50.5 mm

  • Output

    Pulse

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI

  • Specialities

    Commissioning with ReadWin2000

  • Components

    Density Computer FML621

  • Other approvals and certificates

    SIL2/ SIL3