Liquiphant FTL33 - Vibronic point level detection

Vibronic
Point level detection
Liquiphant FTL33

Point level switch for liquids in compact hygienic design for the food industry

FTL33
Please Wait (spinning wheel)
Loading price
Prices temporarily unavailable
Price on request
activating price
price: provide information
from CHF ??.-
Filter Measuring / Application task
Measuring / Application task

Configure to download the CAD drawings of this product

  • Measuring principle

    Vibration Liquids

  • Characteristic / Application

    Point level switch for liquids
    in the food sector

  • Supply / Communication

    20 ... 253V AC/DC, 2-wire
    10 ... 30V DC-PNP, 3-wire

  • Ambient temperature

    -40 °C ... 70 °C
    (-40 °F ... 158 °F)

  • Process temperature

    -40 °C ... 150 °C
    (-40 °F ... 302 °F)

  • Process pressure / max. overpressure limit

    Vacuum ... 40 bar
    (Vacuum ... 580 psi)

  • Min. density of medium

    >0,7g/cm³
    (>0,5g/cm³ optional)

  • Main wetted parts

    316L

  • Process connection

    Threads:
    G1/2, G3/4, G1, MNPT1/2, MNPT3/4, MNPT1, R1/2, R3/4, R1

  • Process connection hygienic

    Flush mount by use of weld in adapter
    DIN11851
    Tri-Clamp

  • Communication

    AC/DC, DC-PNP, IO-Link

  • Certificates / Approvals

    CSA C/US, EAC

  • Safety approvals

    Overfill protection WHG
    Leakage

  • Design approvals

    EN 10204-3.1

  • Hygienic approvals

    3A, EHEDG

  • Options

    Switching delay
    Cleaned from oil+grease,
    Surface finish measurement