Try searching by key words, order- or product code or serial number e.g. “CM442” or “Technical information”
Enter at least 2 characters to start the search.
Nivotester FTL825 FailSafe - Vibronic point level detection

Vibronic
Point level detection
Nivotester FailSafe FTL825

Point level switching unit for Liquiphant FailSafe FTL80, FTL81 and FTL85

FTL825
Please Wait (spinning wheel)
Loading price
Prices temporarily unavailable
Price on request
activating price
price: provide information
from CHF ??.-
Filter Measuring / Application task
Measuring / Application task

Configure to download the CAD drawings of this product

  • Measuring principle

    Vibration Liquids

  • Characteristic / Application

    FailSafe level transmitter point level.
    Top hat rail mounting
    Connection to FTL80/81/85
    Permanent self-monitoring,LIVE-Signal.

  • Specialities

    SIL 3 according to IEC61508.

  • Supply / Communication

    85 - 253 VAC/DC
    20 - 30 VAC/20-60VDC

  • Ambient temperature

    –20 to +60 °C
    (–4 to +140 °F)

  • Communication

    2x SPST safety contact point level
    1x SPST signal contact
    1X SPDT fault contact

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, NEPSI

  • Safety approvals

    Overfill protection WHG
    Leakage Detection

  • Marine approval

    GL/ ABS/ LR/ BV/ DNV