Try searching by key words, order- or product code or serial number e.g. “CM442” or “Technical information”
Enter at least 2 characters to start the search.
Waterpilot FMX11 - Hydrostatic level measurement

Hydrostatic Level measurement
Waterpilot FMX11

Simple and reliable level probe for freshwater applications

FMX11
Please Wait (spinning wheel)
Loading price
Prices temporarily unavailable
Price on request
activating price
price: provide information
from CHF ??.-
Filter Measuring / Application task
Measuring / Application task

Configure to download the CAD drawings of this product

  • Measuring principle

    Hydrostatic pressure

  • Characteristic

    Compact probe with metallic cell for hydrostatic level measurement
    in fresh water, ground water and potable water storage.

  • Supply voltage

    8...28 VDC

  • Reference Accuracy

    pn ≥ 400mbar: 0.35 %
    pn < 400mbar: 0.50 %

  • Long term stability

    0.1 % of URL/year

  • Process temperature

    -10°C...+70°C
    (+14°F...+158°F)

  • Ambient temperature

    -10°C...+70°C
    (+14°F...+158°F)

  • Measuring cell

    200 mbar...2 bar
    (3 psi...29 psi)

  • Process connection

    Suspension clamp
    Cable mounting screws

  • Material process membrane

    Metal

  • Communication

    4...20 mA

  • Drinking water approvals

    NSF, KTW, ACS

  • Measuring principle

    Hydrostatic

  • Characteristic / Application

    Compact probe with metallic cell for hydrostatic level measurement
    in fresh water, ground water and potable water storage.

  • Supply / Communication

    8...28 VDC

  • Accuracy

    pn ≥ 400mbar: 0.35 %
    pn < 400mbar: 0.50 %

  • Long term stability

    0.1% of URL/year

  • Ambient temperature

    -10°C...+70°C
    (+14°F...+158°F)

  • Process temperature

    -10°C...+70°C
    (+14°F...+158°F)

  • Process pressure / max. overpressure limit

    10 bar (145 psi)

  • Pressure measuring range

    200 mbar...2 bar
    (3 psi...29 psi)

  • Main wetted parts

    316L

  • Process connection

    Suspension clamp
    Cable mounting screws

  • Max. measurement distance

    20 m H2O
    (66 ft H2O)

  • Communication

    4...20 mA

  • Drinking water approvals

    NSF, KTW, ACS