The RLN22 is a compact 1- or 2-channel, 24 VDC isolating amplifier with relay signal output. It is designed to safely operate e.g. proximity sensors or point level switches such as the Liquiphant FTL51B (NAMUR) as per IEC 60947-5-6. The DC interface monitors line faults such as breaks or short-circuits of sensors or mechanical switching contacts. The device is suited for use in hazardous areas and safety instrumented systems up to SIL 2 in accordance with IEC 61508.
Isolating amplifier for the transmission of binary switching signals
Input for proximity sensors, open contacts or contacts with resistive coupling elements
Galvanic isolation (3-way)
Line fault monitoring of input circuits or mechanical switching contacts
Group error message via DIN rail bus connector
Output-side relay contacts, direction of action (operating or quiescent current behavior) via DIP switch selection
Ambient temperature range: –40 to 60 °C (–40 to 140 °F)
Benefits
Safe and reliable switching operations: trust your critical applications
Compact housing: up to 2 channels on 12.5 mm (0.49 in) for efficient use of space in control cabinets
Installation in hazardous areas; Ex approval for Ex zone 2
Up to SIL 2 in accordance with IEC 61508
Quick and easy wiring and commissioning: plug-in terminals, power supply and group error message module via DIN rail bus connector
Digital communications now provide a wealth of additional diagnostic and other information, enabling operational insights unachievable with simple 4-20mA measurements alone.
Goulston Technologies, Inc, in North Carolina, finds reliable and cost saving solutions by implementing Endress+Hauser's Advanced Data Manager Memograph RSG45 technology.
Over the years, variations of the activated sludge treatment process have surfaced to improve performance or reduce operating costs. Download the Q&A to learn about a new technology, Nereda®!
RLN22: 1- oder 2-kanaliger NAMUR-Trennschaltverstärker mit
Relais-Signalausgang
CONTROL/INSTALLATION DRAWING for explosion h
azardous areas according to
Direc. 2014/34/EU (ATEX)
Ex Safety Instruction (XA)
English version - 08/2024
New version available in English
ATEX/UKCA: ATEX II (1) G [Ex ia Ga] IIC, II (1) D [Ex ia Da] IIIC, II3(1) G Ex ec nC [ia Ga] IIC T4 Gc IECEx: [Ex ia Ga] IIC, [Ex iaDa] IIIC, Ex ec nC [ia Ga] IIC T4 Gc
Lösungen zur Komplettierung der Messstelle Anzeiger, Interfacegeräte, Überspannungsschutz, Energie- und Applikationsmanager, Datenmanager, Bildschirmschreiber und Softwarepakete für die Prozessautomatisierung
Solutions for the loop Indicators, interface devices, surge arresters, energy and application managers, data managers, paper less recorders and associated software packages for process automation