The RNO22 output isolating amplifier is used to safely control active components such as control valves, actuators, I/P converters or indicators. The intrinsically safe device separates and transmits analog 0/4 to 20 mA signals and offers bidirectional HART® transparency for digital communication with smart actuators. The compact interface device with up to two galvanically isolated channels enables open- and short-circuit monitoring for reliable operation of critical equipment.
1- or 2-channel output isolating amplifier
Reliable control of active components such as control valves, current-to-pressure transducers
Transmission and galvanic isolation of 0/4 to 20 mA signals
Intrinsically safe [Ex-ia], installation in Ex Zone 2
Suited for use in safety instrumented systems up to SIL 2 (SC 3) in accordance with IEC 61508
Bidirectional transmission of digital HART® communication signals
Ambient temperature range: –40 to 70 °C (–40 to 158 °F)
Benefits
Safe and reliable control of active components in hazardous areas
Quick and easy wiring and commissioning: plug-in terminals, power supply via DIN rail bus connector
Compact housing: up to 2 channels on 12.5 mm (0.49 in) for efficient use of space in control cabinets
Digital communications now provide a wealth of additional diagnostic and other information, enabling operational insights unachievable with simple 4-20mA measurements alone.
Goulston Technologies, Inc, in North Carolina, finds reliable and cost saving solutions by implementing Endress+Hauser's Advanced Data Manager Memograph RSG45 technology.
Over the years, variations of the activated sludge treatment process have surfaced to improve performance or reduce operating costs. Download the Q&A to learn about a new technology, Nereda®!
RNO22 Output amplifier 24V DC
CONTROL/INSTALLATION DRAWING for explosion hazardous areas according
to Dir. 2014/34/EU (ATEX)
Ex Safety Instruction (XA)
English version - 09/2022
New version available in English
IECEx: [Ex ia Ga] IIC, [Ex ia Da] IIIC, Ex ec nC [ia Ga] IIC T4 Gc ATEX/UKCA: ATEX II (1) G [Ex ia Ga] IIC, II (1) D [Ex ia Da] IIIC, II 3(1) G Ex ec nC [ia Ga] IIC T4 Gc
Lösungen zur Komplettierung der Messstelle Anzeiger, Interfacegeräte, Überspannungsschutz, Energie- und Applikationsmanager, Datenmanager, Bildschirmschreiber und Softwarepakete für die Prozessautomatisierung